Multipipe Pumpstations
Pumpstations are a new way to bring together multiple heat types onto a single point of distribution, making this ideal for where you have high-temperature and low-temperature parts to your heating system.
This unit is ideal where mixing is not required, but there is a need to monitor system temperature. Perfect for radiators and/or hot water cylinders that require high temperatures.
Benefits
- Significant energy savings
- Quicker and neater installations
- Pre-assembled pipework for speedier finish
Pumpstation
Part Code | Description |
---|---|
40-DN2001 | DN20 – Direct flow (no mix) with isolator and pump |
Header
Part Code | Description |
---|---|
40-DN2022 | 2-Port DN20 header with hydraulic separator |
40-DN2023 | 3-Port DN20 header with hydraulic separator |
Technical Specification
A+ rated pump, with anti-syphon valve and a combined temperature and insulation valve
Description | Detail |
---|---|
Product Code (panel only) | 40-DN2502 |
Working Temperature Range | 5-90°C |
Mixing Temperature Range | 20-60°C |
Max Working Pressure | 10 bar |
Connections Secondary side | 1″ BSP Female (Parallel) |
Pump | Wilo para 25-180/7-50/SC-12 |
Acceptable fluids | Water, Glycol Mix (max 30%) |
Insulation Material | Expanded Polypropylene (EPP) |
Thermal Conductivity (K value) | 0.04 W/mK |
Component Material | Brass CW617N |
Extension Material | Steel |
Ideal for UFH, Towel rails and other low temperature systems that require a set controlled temperature
Benefits
- Significant energy savings
- Quicker and neater installations
- Pre-assembled pipework for speedier finish
Pumpstation
Part Code | Description |
---|---|
40-DN2002 | DN20 – Fixed temperature mix with isolator and pump |
Header
Part Code | Description |
---|---|
40-DN2022 | 2-Port DN20 header with hydraulic separator |
40-DN2023 | 3-Port DN20 header with hydraulic separator |
Technical Specification
A+ rated pump, with anti-syphon valve and a combined temperature and insulation valve
Description | Detail |
---|---|
Product Code (panel only) | 40-DN2502 |
Working Temperature Range | 5-90°C |
Mixing Temperature Range | 20-60°C |
Max Working Pressure | 10 bar |
Connections Secondary side | 1″ BSP Female (Parallel) |
Pump | Wilo para 25-180/7-50/SC-12 |
Acceptable fluids | Water, Glycol Mix (max 30%) |
Insulation Material | Expanded Polypropylene (EPP) |
Thermal Conductivity (K value) | 0.04 W/mK |
Component Material | Brass CW617N |
Extension Material | Steel |
Ideal for low temperature system that need variable temperature depending on weather conditions for increased efficiency
Benefits
- Significant energy savings
- Quicker and neater installations
- Pre-assembled pipework for speedier finish
Pumpstation
Part Code | Description |
---|---|
40-DN2007 | DN20 – Variable temperature mix with isolator and pump Excl. Actuator and controller (Valve Kv-4) |
Header
Part Code | Description |
---|---|
40-DN2022 | 2-Port DN20 header with hydraulic separator |
40-DN2023 | 3-Port DN20 header with hydraulic separator |
Technical Specification
A+ rated pump, with anti-syphon valve and a combined temperature and insulation valve
Description | Detail |
---|---|
Product Code (panel only) | 40-DN2502 |
Working Temperature Range | 5-90°C |
Mixing Temperature Range | 20-60°C |
Max Working Pressure | 10 bar |
Connections Secondary side | 1″ BSP Female (Parallel) |
Pump | Wilo para 25-180/7-50/SC-12 |
Acceptable fluids | Water, Glycol Mix (max 30%) |
Insulation Material | Expanded Polypropylene (EPP) |
Thermal Conductivity (K value) | 0.04 W/mK |
Component Material | Brass CW617N |
Extension Material | Steel |